0 11zon

A simple solution for networking Modbus equipment

Real Time Modbus RTU to Modbus TCP converter
Model RMC11

RMC11 is an industrial Real Time Modbus RTU to Modbus TCP converter designed to integrate RS-485 serial devices with Ethernet networks. This converter enables stable and transparent communication between Modbus RTU-based devices and Modbus TCP-based monitoring or control systems.

On the Modbus RTU side, the RMC11 converter has no limitation on the number of connected devices and can easily manage multiple serial devices. On the Modbus TCP side, this model supports one Device (Client/Server), making it an ideal option for simple, stable, and cost-effective projects.

  • For projects that require support for multiple Devices on the TCP side, the RMC12 model is offered as a more advanced version.

0 11zon
مبدل-دو-طرفه

Modbus Converter

Two-way Modbus RTU ↔ Modbus TCP Converter

پورت

RS-485 Interface

RS-485 communication interface on the RTU side

نامحدود-دستگاه

Unlimited RTU

No limitation on the number of Modbus RTU devices

تک-دستگاه

Single TCP Device

Supports one Device on the Modbus TCP side

آیکون-راه-اندازی

Easy Setup

Simple installation and commissioning with flexible configuration settings

کاربردها

Due to its industrial design and high compatibility, this product is used in various applications such as industrial automation, control panels, energy monitoring systems, PLCs, HMIs, and SCADA.

کاربردها
پروتکل

* Modbus TCP over LAN

  • * Modbus RTU over RS-485

With support for the Modbus TCP protocol, if you are using PLCs or DCSs that do not support RS-485 networks but have a LAN port and communicate via Modbus TCP, they can write their data through this converter.

پروتکل

جهت دریافت تمامی ویدئوهای فعلی و جدیدترین ویدئوهای ضبط شده با موضوعات اتصال و راه اندازی محصول و ارتباط با انواع PLC و HMI کلیک کنید.

VIDEO

Connecting PLCs to Instrumentation Equipment

اتصال به انواع سنسور RLD50 D

Product-Related Questions

Yes. These sensors can be connected to various computers (regardless of the operating system) using RS-485 to USB converters.

Your technical questions about the product can be sent as text messages (SMS or social media) to the support team, and the technical experts will respond through the same channels. If needed, they will contact you directly.

Sales and Support Team Number:
+989177391091

Yes. Since the device enclosure has an IP66 protection rating against water and dust ingress, this product can be used in outdoor environments. However, it is not recommended to expose it continuously to rain or direct water spray.

Due to the protective cover on the sensor, sudden sprays of non-acidic liquids are repelled and do not cause any damage to the sensor.

Since this sensor communicates via the Modbus protocol with devices such as PLCs, RTUs, and HMIs, you can view the measurements on industrial HMI displays and your personal computer monitor.

Yes. One meter of flexible four-core cable (power + RS-485) with a thickness of 0.25 mm² is included with the product.

Via the Modbus-RTU network

Yes, the sensor’s slave address can be changed via software using Modbus commands.

The components used in this sensor are manufactured in the USA and Switzerland.

Yes, according to Modbus protocol standards, this is possible. For more information and details on how to differentiate sensor data, you can refer to the sensor setup tutorial file.

You can find all tutorials and necessary files on the product page under the “Product Videos” and “Downloadable Files” tabs. Click here.

Some PLCs have an RS-485 port, allowing the sensor to connect directly. However, for PLCs without an RS-485 port, the sensors must be connected via RS-485 expansion cards.

Due to the sensor’s casing material, it cannot be installed directly inside a furnace. However, the company can provide the sensor with a half-meter cable, allowing customers to place the sensor circuitry outside while installing the sensor itself inside the furnace.